[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] RE: [FW1] Nokia IP400 Series and CP 4.1 Enterprise Logging
What type of management station are you running ? NT ? I did an upgrade from FW1 4sp4 to 4.1 sp2 and ran into the same problem. Problem was attributed to management station. Had played with control.map and putkeys to no avail. Ended up saving objects.C and rulebase files then uninstalling fw ms...then reinstalling fw mangement station. Then used fw conferge to merge the old objects.C with the new. Copied the rulebase and merged objects.C into the mangement station and was off to the races. Once of course resetting the license and putkeys.. Kip Pesterfield Sr. Network Engineer Exodus Communications [email protected] celldesk-----Original Message----- From: John Warner [mailto:[email protected]] Sent: Tuesday, October 03, 2000 4:42 AM To: [email protected] Subject: [FW1] Nokia IP400 Series and CP 4.1 Enterprise Logging We installed a Nokia IP 400 Series on Saturday. We are able to push policy from our server to the module, however the logging that takes place on the server stopped. Anyone have any ideas? John Warner Network Administrator Jabil Circuit, Inc.======================================================================== ======== To unsubscribe from this mailing list, please see the instructions at http://www.checkpoint.com/services/mailing.html ======================================================================== ======== ================================================================================ To unsubscribe from this mailing list, please see the instructions at http://www.checkpoint.com/services/mailing.html ================================================================================
|